Fitting Tab (Hole Fitting Properties Dialog) - Intergraph Smart 3D - Help - Hexagon PPM

Intergraph Smart 3D Hole Management

Language
English
Product
Intergraph Smart 3D
Subproduct
Hole Management
Search by Category
Help
Smart 3D Version
13

Specifies the general properties of an outfitting catalog hole fitting. This tab is only available when you place catalog fittings. Please note that pipe fitting by rule are not catalog fittings.

Fitting Type

Select the hole fitting to place with the hole. If By Rule is selected, then this option is disabled.

By rule

Select to allow the software to automatically select the fitting type according to Fitting Selection Rules in the software.

Fitting Selection

Specify the rule used to select the fitting type.

Name

Displays the name of the hole fitting. You can define the name yourself by setting the Rule box to User Defined.

Parent

Select the parent system for the hole fitting object. The structural or catalog hole fitting is the child of the hole fitting objects.

Rule

Select the Hole Naming Rules to use to name the hole fitting. Select User Defined to define the name yourself in the Name box. Outfitting catalog hole fittings use the general outfitting naming rules.

Category

Select the class of catalog fitting properties you want to view. For more information about catalog fittings, see Fitting Worksheets.

Property

Name of the catalog fitting property.

Values

Value of the catalog fitting property.