Specifies the properties for the select designed member.

Category

Select the properties that you want to view for the member. Only Standard properties are available for designed members.

Show Dimensional Legend

Displays a graphic indicating the different dimensions that can be specified for the selected designed member.

Standard

Name

Displays the name of the designed member. The designed member name is based on the Name Rule selection. To type a new name for the designed member, select User Defined in the Name Rule box, and then type a name for the designed member in the Name box.

Name Rule

Specify the naming rule to use to name this designed member. You can select one of the listed rules or select User Defined and type the designed member name in the Name box.

Parent System

Specifies the name of the parent system. You can define new systems in the Systems and Specifications task.

Section Standard

Specifies the cross-section library from which to select the cross section. Section libraries and cross-sections are defined in the reference data.

Cardinal Point

Specifies the relative position of the structural cross-section to the member placement line. Nine cardinal positions (1-9) are available. The location of cardinal points 10 (center-of-gravity) and 15 (shear center) depend on the section shape. The local z-axis of the member and the center-of-gravity point of the section define cardinal points 11 and 14. The local y-axis of the member and the center-of-gravity point of the section define cardinal points 12 and 13. Cardinal points 10 through 15 are unavailable for designed members or cans.

Angle

Defines the angle by which the section is rotated about the member axis.

Reflect

Reflects or mirrors the cross-section about the member's local z-axis. This parameter affects both symmetric and asymmetric sections. An example of when to use this option is when you want the flanges of a channel section to point in the opposite direction.

Type category

Specifies the type category of the member, such as a beam or a column. The available member type and properties change depending on the member type category that you select. You can define a custom member type category by editing the Structural Member Type list in the Catalog task.

Type

Specifies the type of member, such as a beam or column. The available member properties change depending on the member type that you select. This property is a hierarchical child of Type Category. To change the options on the list, edit the Structural Member Type select list in Catalog.

Priority

Specifies the priority assigned to the object system. Smart 3D uses the priority to group objects. To change the options on the list, edit the Structural Member Priority select list in Catalog.

Centroid X

Specifies the location of the centroid along the local x-axis. This property is read-only. To edit this value, you need to edit the cross-section's properties in Catalog or in the corresponding workbook.

Centroid Y

Specifies the location of the centroid along the local y-axis. This property is read-only. To edit this value, you need to edit the cross-section's properties in Catalog or in the corresponding workbook.

Moment of Inertia about X (Ixx)

Specifies the moment of inertia for the section's local x-axis. This property is read-only. To edit this value, you need to edit the cross-section's properties in Catalog or in the corresponding workbook.

Moment of Inertia about Y (Iyy)

Specifies the moment of inertia for the section's local y-axis. This property is read-only. To edit this value, you need to edit the cross-section's properties in Catalog or in the corresponding workbook.

Warping Statical Moment (Sw)

Specifies the warping statical moment. This property is read-only. To edit this value, you need to edit the cross-section's properties in Catalog or in the corresponding workbook.

Elastic Section Modulus about X (Sxx)

Specifies the section modulus for the section's local x-axis. This property is read-only. To edit this value, you need to edit the cross-section's properties in Catalog or in the corresponding workbook.

Elastic Section Modulus about Y (Syy)

Specifies the section modulus for the section's local y-axis. This property is read-only. To edit this value, you need to edit the cross-section's properties in Catalog or in the corresponding workbook.

Torsional Moment of Inertia (J)

Specifies the torsional moment of inertia for the section. This property is read- only. To edit this value, you need to edit the cross-section's properties in Catalog or in the corresponding workbook.

Warping Constant (Cw)

Specifies the warping constant for the section. This property is read-only. To edit this value, you need to edit the cross-section's properties in Catalog or in the corresponding workbook.

Flexural Constant (H)

Specifies the flexural constant for the section. This property is read-only. To edit this value, you need to edit the cross-section's properties in Catalog or in the corresponding workbook.

Polar Radius of Gyration about Shear Center (ro)

Specifies the polar radius of gyration about the shear center. This property is read-only. To edit this value, you need to edit the cross-section's properties in Catalog or in the corresponding workbook.

Radius of Gyration about X axis (Rxx)

Specifies the radius of gyration for the section's local x-axis. This property is read-only. To edit this value, you need to edit the cross-section's properties in Catalog or in the corresponding workbook.

Radius of Gyration about Y axis (Ryy)

Specifies the radius of gyration for the section's local y-axis. This property is read-only. To edit this value, you need to edit the cross-section's properties in Catalog or in the corresponding workbook.

Radius of Gyration about Principle XY (Rxy)

Specifies the radius of gyration about the principle xy-axis. This property is read-only. To edit this value, you need to edit the cross-section's properties in Catalog or in the corresponding workbook.

Plastic Section Modulus about X (Zxx)

Specifies the plastic section modulus for the section's local x-axis. This property is read-only. To edit this value, you need to edit the cross-section's properties in Catalog or in the corresponding workbook.

Plastic Section Modulus about Y (Zyy)

Specifies the plastic section modulus for the section's local y-axis. This property is read-only. To edit this value, you need to edit the cross-section's properties in Catalog or in the corresponding workbook.

Is Hollow

Specifies True if the cross-section is hollow, such as a tube or can. Specifies False if the cross-section is solid, such as a bar, or open, such as an I-beam.

Is Symmetric about X

Specifies True if the cross-section is symmetric about the local x-axis of the cross-section.

Is Symmetric about Y

Specifies True if the cross-section is symmetric about the local y-axis of the cross-section.

Section Properties

Specifies section properties as being defined by system or by user.

Area

Specifies the cross-section area for the object. This property is read-only. To change this value, edit the object properties in Catalog or in the corresponding workbook.

Depth

Specifies the depth for the section. This property is read-only. To edit this value, you need to edit the cross-section's properties in Catalog or in the corresponding workbook.

Width

Specifies the flange width for the section. This property is read-only. To edit this value, you need to edit the cross-section's properties in Catalog or in the corresponding workbook.

Perimeter

Specifies the outside perimeter distance for the section. This property is read-only. To edit this value, you need to edit the cross-section's properties in Catalog or in the corresponding workbook.

Unit Weight

Specifies the weight of the section. The unit weight is defined in mass per length pound per foot (lbm/ft). This property is read-only. To edit this value, you need to edit the cross-section's properties in the Catalog task or in the corresponding workbook.

Length Extension

Specifies the extension added to the member length to accommodate non-orthogonal connections. The default value is 0.

Width - Top Flange

Displays the width of the top flange

Width Extension - Top Flange

Specifies the extension added to the top flange length to accommodate non-orthogonal connections. The default value is 0.

Depth Extension

Specifies the extension added to the member depth to accommodate non-orthogonal connections. The default value is 0.