These properties specify extra rod connection properties for welded beam attachments. This is an optional geometry that is used to create the nipple-type object seen on some bolted ceiling flanges.

These properties are also used in conjunction with the side, top and bottom plate graphics to create isolation dampers. The extra rod connection is inside the WBA Hole graphics instead of below. This is most commonly used with only the concrete plate.

An extra rod connection cannot exist individually. It must either have a concrete plate or WBA Hole graphics.

IJUAhsShapeType::ShapeType

This value specifies the graphic shape to be used for the extra rod connection. The value for this column is a codelist number and valid codes are listed in the HS_S3DParts_Codelist.xls workbook of the hsShapeType sheet. Enter the shortName of codelist for readability in the workbook.

1 - Round

2 - Square

3 - Hex

IJUAhsThickness5::Thickness5

Enter the thickness of the extra rod connection shape from the lower face of the base plate to the lower face of the extra rod connection. If this value is set to a negative, the thickness is started at the upper surface of the base plate bottom and extends up. If this value is zero, the extra rod connection is not shown.

IJUAhsWidth5::Width5

Enter the outside dimension of the extra rod connection shape.

1 - Round

2 - Square

3 - Hex