Hold-Down Bolts Properties - Intergraph Smart 3D - Reference Data

Intergraph Smart 3D Hangers and Supports SmartParts Configuration

Language
English
Product
Intergraph Smart 3D
Subproduct
3D Symbols
Search by Category
Reference Data
Smart 3D Version
12 (2018)

These properties are optional. Enter values for these properties to add bolt geometry to the strap. One row of any number of bolts on either side of strap can be added; however, both sides must have the same number of bolts, the same offset from the strap centerline, and the same spacing within the row of bolts. There are no separate nuts.

IJUAhsPin1::Pin1Diameter (Optional)

Specifies the pin diameter of all bolts. If Pin1Diameter is set to 0, then no bolts are shown.

IJUAhsPin1::Pin1Length (Optional)

Specifies the pin length for all bolts. All bolts have the same length, starting at Offset2 above the bottom of the strap. If Pin1Length is set to zero, bolts are still shown.

IJUAOffset1::Offset1 (Optional)

Specifies the offset of the bolt row from the pipe centerline. This value is always positive.

IJUAOffset2::Offset2 (Optional)

Specifies the offset of the start of the bolts above the bottom of the strap.

IJUAhsMulti1::Multi1Qty (Optional)

Specifies the quantity of bolts. Bolts are not shown on the strap when Multi1Qty is set to zero. Valid cases are shown in the example below.

IJUAhsMulti1::Multi1LocateBy (Optional)

Specifies the location of the bolts. Individual bolts can be located in two ways.

1 - Relative to center of the group
2 - Relative to edge.

The exact meaning depends on the quantity of bolts. This value can be 0 (nothing), 1 (center), or 2 (edge). Valid cases are shown in the example below.

IJUAhsMulti1::Multi1Location (Optional)

Specifies the distance for the exact location of the bolts depending on Multi1LocateBy and Multi1Qty. This value can be either a distance to the edge or a center-to-center spacing. Valid cases are shown in the example below.

Example: Valid Multi1Qty, Multi1LocateBy, Multi1Location cases: