IJUAhsTopPlate::TopPlateThickness
Specifies the thickness of the top plate.
IJUAhsTopPlate::TopPlateHeight
Specifies the height of the top plate. If the value is zero, the height is calculated from the symbol code based on the specified Gap and TopPlateOffset.
IJUAhsTopPlate::TopPlateLength
Specifies the length of the top plate.
IJUAhsTopPlate::TopPlateGap
Specifies the gap between the top of the shoe and the bottom of the pipe.
IJUAhsTopPlate::TopPlateOffset
Specifies the vertical downward offset of the extension plate from the top of the shoe.
IJUAhsTopPlate::Inside
Determines whether the extension plate is attached to the inside or outside the vertical plates. Enter codelist value 0 for inside or 1 for outside. The coldelist values are defined on the hsExtensionType sheet in the HS_S3DParts_Codelist.xls workbook.
IJUAhsTopPlate::Extension
Specifies if the extension plate is used or not. Extension plates are not supported for ShoeTypes 7, 8, 9 and 10.
IJUAhsExtPltOff::ExtensionPlateAxialOffset
Specifies a value to offset the extension plate along the x-axis of the pipe.