Lower Plate Shield Properties - Intergraph Smart 3D - Reference Data - Hexagon PPM

Intergraph Smart 3D Hangers and Supports SmartParts Configuration

Language
English
Product
Intergraph Smart 3D
Subproduct
Hangers and Supports
Search by Category
Reference Data
Smart 3D Version
13

IJUAhsThickness1::Thickness1

Specifies thickness of the lower curved plate. This value must be greater than zero.

IJUAhsLength1::Length1

Specifies the length of the lower plate. This value must be greater than or equal to zero.

IJUAhsAngle1::Angle1

Specifies the angle from vertical center line of the pipe to the left edge of the plate. Angle1 and Angle2, or Width1 and Width2, can define the sweep of the plate. Angle1 and Angle2 take precedence. If there is no top plate then:

Angle1 <= 360 degrees – Angle2

Else if there is a top plate then

Angle1 <= 180 degrees – Angle3

IJUAhsAngle2::Angle2

Specifies the angle from vertical center line of the pipe to the right edge of the plate. Angle1 and Angle2, or Width1 and Width2, can define the sweep of the lower plate. Angle1 and Angle2 take precedence. If there is no top plate then:

Angle2 <= 360 degrees – Angle1

Else if there is a top plate then

Angle2 <= 180 degrees – Angle4

IJUAhsWidth1::Width1

Specifies the distance from vertical center line of the pipe to the left inside edge of the plate. Curved plate only drawn on the lower half of the pipe. Angle1 and Angle2 must be 0 or this will be ignored. Width1 must be less than 0.5 * PipeOD.

IJUAhsWidth2::Width2

Specifies the distance from vertical center line of the pipe to the right inside edge of the plate. Curved plate only drawn on the lower half of the pipe. Angle1 and Angle2 must be 0 or this will be ignored. Width2 must be less than 0.5 * PipeOD.