The software adds equally spaced layers using the data below. The insulation layers do not increase the overall length of the insulation. The outer layers are shorter than Length. Not all dimensions are required. If a dimension is blank or equal to zero, the part creates the dimension based on the provided rule. If no rule is provided, the part ignores the dimension.

IJUAhsLayerQty::LayerQty

Specifies the number of layers to be shown. This value is optional. Valid values are from 1 to 5. If LayerQty is equal to one, then do not show any additional layers. If LayerQty is greater than one, then add the layers as shown. The diameter of the layers is calculated using the below function:

IJUAhsOffset1::Offset1

Specifies the offset of the layers from the length of the insulation. This value is optional. If LayerQty is equal to one, then this value is ignored. If LayerQty is greater than one, then each layer is an inset by the same offset from the previous layer. The layer closest to the pipe contains length = Length. Subsequent layers contains their length calculated using the below function: