These properties define the geometry of the bottom shape of the clevis hanger.
IJUAhsWidth2::Width2
Specifies the width of the bottom portion of the clevis hanger. This value is always greater than Pin1Diameter. If this value is less than or equal to Pin1Diameter, then the software sets Width1 as the default value.
IJUAhsThickness2::Thickness2
Specifies the thickness of the bottom portion of the clevis hanger. This value is always greater than or equal to zero. If this value is equal to zero, then the software sets Thickness1 as the default value.
IJUAhsHeight5::Height5
Specifies the height from the pipe centerline to the top-most edge of the bottom section of the clevis hanger. If this value is less than 0.5 * Diameter1 + Pin1Diameter, then the software sets RodTakeOut - 5 * Pin1Diameter as the default value.
IJUAhsHeight6::Height6
Specifies the height from the pipe centerline to the top edge of the angled section of the clevis hanger. Presuming the vee is a 45-degree angle, if ClevisBotShp = 1, then this value is ignored; however, if this value is less than or equal to 0, then the software sets Height7 - 0.5 * Diameter1 as the default value.
IJUAhsHeight7::Height7
Specifies the height from the pipe centerline to the bottom of the angled section of the clevis hanger. Presuming the vee is a 45-degree angle, if ClevisBotShp = 1, then this value is ignored; however, if this value is less than or equal to 0, then the software sets Height7 - 0.5 * Diameter1 / sin(45) as the default value.