IJUAhsSupportNumber::SupportNumber
Defines the support detail number as specified on the support specification. This value is used by the default BOM function when generating the BOM Description for the support.
IJUAhsSteelStandard::SteelStandard
Defines the steel standard used by the support. If external rules were written to select the steel section, this attribute would be used to determine the standard to use.
IJUAhsFrameType::FrameType
Defines the type of the frame shape. This attribute is used by rules to determine what type of frame the support is. Additional code-List values can be added as required. Accepted values from the hsFrameType codelist in the HS_S3DAssy_Codelist.xls workbook are shown below:
-
1 - U-Frame
-
2 - L-Frame
-
3 - T-Frame
-
5 - I-Frame
-
6 - Box Frame
IJUAhsFrameConfiguration::FrameConfiguration
Defines the initial frame configuration on placement. This property is applicable
only to U, L, Box Frame, and T-Frames types. You can change the configuration after
placing the support by clicking Change Support Configuration on the ribbon. Accepted values are:
-
1 - Frame support placed on the far side of the pipe.
-
2 - Frame support placed on the closest side of the pipe.
IJUAhsFrameOrientation::FrameOrientation
Defines the frame support orientation with respect to the supporting object or the global coordinate system. Accepted values from the hsFrameOrientation codelist in the HS_S3DAssy_Codelist.xls workbook are:
-
1 - Direct - Frame support orients directly towards the supporting object.
Direct Orientation to planar object
Direct Orientation to Curved Object
-
2 - Orthogonal - Frame support orients orthogonally to the global coordinate system.
Orthogonal orientation to planar object
Orthogonal orientation to curved object
-
3 - Tangent - Frame support orients tangent to the first and last selected pipes.
Tangent orientation to planar object
Tangent orientation to curved object
IJUAhsMirrorFrame::MirrorFrame
Mirrors the frame support about the bounding box. Accepted values are shown below:
-
0 - False
-
1 - True
IJUAhsIncludeInsulation::IncludeInsulation
Specifies whether the frame should adjust its size to include pipe insulation.
-
0 - False
-
1 - True
IJUAhsStructureConn::StructureConnection
Specifies how the hanger beam part is connected to the structure. Allowed values in the codelist are:
-
Normal
-
Lapped
-
Lapped-Opposite