IJUAhsSupportNumber::SupportNumber
Defines the support detail number as specified in the support specification. This value is used by the default BOM function when generating the BOM Description for the support.
IJUAhsSteelStandard::SteelStandard
Defines the steel standard used by the support. If there are any external rules for the steel section, this attribute is used to determine standard to use.
IJUAhsFrameType::FrameType
Defines the type of the frame shape. This attribute is used by the rules to determine the support frame type. You can add additional code-List values as required. The accepted values from the hsFrameType codelist in the HS_S3DAssy_Codelist.xls workbook are as shown below:
-
9 - Cantilevers
-
10 - Braced Cantilevers
IJUAhsFrameOrientation::FrameOrientation
Defines the frame support orientation with respect to the supporting object or the global coordinate system. The accepted values from the hsFrameOrientation codelist in the HS_S3DAssy_Codelist.xls workbook are as shown below:
-
1 - Direct Orientation
-
2 -Orthogonal Orientation
-
3 - Tangent Orientation
IJUAhsMirrorFrame::MirrorFrame
Mirrors the frame about the bounding box. The accepted codelist values are as shown below:
-
0 - False
-
1 - True
IJUAhsIncludeInsulation::IncludeInsulation
Specifies whether the frame should adjust its size to include pipe insulation.
-
0 - False
-
1 - True
IJUAhsStructureConn::StructureConnection
Specifies how the hanger beam part is connected to the structure. The accepted codelist values are as shown below:
-
1 - Normal
-
2 - Lapped
-
3 - Lapped-Opposite