Structural Connection Properties - Intergraph Smart 3D - Reference Data

Intergraph Smart 3D Hangers and Supports Data Driven Assembly Configuration

Language
English
Product
Intergraph Smart 3D
Subproduct
3D Symbols
Search by Category
Reference Data
Smart 3D Version
12.1 (2019)

These properties specify the parts to use for connecting the support to the supporting object.

The following properties are applicable to U, L, T, I, and Box Frame types:

IJUAhsBasePlate1::BasePlate1Part

Specifies the part number or part class of the first base plate. This must be a SmartPart 2 Port Plate. To select the part using BasePlate1Rule, do not type any value for this property.

IJUAhsBasePlate1Rl::BasePlate1Rule

Defines an HgrSupportRule that returns a part number or part class to use for the base plate. The hanger rule must exist in the catalog; it can be a rule name or a ProgID. To select the part directly using BasePlate1Part, do not type any value for this property.

IJUAhsBasePlate1Ang::BasePlate1Angle

Specifies the angle that BasePlate1 should be rotated about the Z-axis of the port to which the plate is attached (either BeginFace or EndFace).

IJUAhsBasePlate1Off::BasePlate1Offset

Specifies the distance by which the base plate should be offset from leg1. BasePlate1Offset is applicable only when StructureConnection is set to either Lapped or Lapped-Opposite.

IJUAhsBasePlate2Off::BasePlate2Offset

Specifies the distance by which the base plate should be offset from leg2. BasePlate2Offset is applicable only when StructureConnection is set to either Lapped or Lapped-Opposite.

IJUAhsBasePlate1Off::BasePlate1Offset

Defines how BasePlate1Offset is measured. BasePlate1OffsetDef specifies the distance between the base plate and leg1.

IJUAhsBasePlate2Off::BasePlate2Offset

Defines how BasePlate2Offset is measured. BasePlate1OffsetDef specifies the distance center of the base plate to the edge of leg2.

IJUAhsBolt1::Bolt1Part

Specifies the part number or the part class of the bolts connected to BasePlate1. To select the part using Bolt1Rule, do not type any value for this property.

IJUAhsBolt1Rl::Bolt1Rule

Defines an HgrSupportRule that returns a part number or the part class to use for the Bolts. The hanger rule must exist in the catalog; it can be a rule name or a ProgID. To specify the part directly using Bolt1Part, do not type any value for this property.

IJUAhsBolt1Qty::Bolt1Quantity

Specifies the quantity of bolts to include on BasePlate1. Usually, 2 or 4.

The following properties are applicable for all frame types:

IJUAhsBolt1Offset1::Bolt1Offset1

Specifies the offset value for Bolt1Part from the edge of the plate to the center of the bolt along the x-axis of the pipe.

IJUAhsBolt1Offset2::Bolt1Offset2

Specifies the offset value for Bolt1Part from the edge of the plate to the center of the bolt along the y-axis of the pipe.

The following properties are applicable for U-Frame type only:

IJUAhsBasePlate2::BasePlate2Part

Specifies the part number or part class of the second base plate. This must be a SmartPart 2 Port Plate. To select the part using BasePlate2Rule, do not type any value for this property.

IJUAhsBasePlate2Rl::BasePlate2Rule

Defines an HgrSupportRule that returns a part number or part class to use for the base plate. The hanger rule must exist in the catalog; it can be a rule name or a ProgID. To select the part directly using BasePlate2Part, do not type any value for his property.

IJUAhsBasePlate2Ang::BasePlate2Angle

Specifies the angle that BasePlate2 should be rotated about the Z-axis of the port to which the plate is attached (either BeginFace or EndFace).

IJUAhsBolt2::Bolt2Part

Specifies the part number or the part class of the bolts connected to BasePlate2. To select the part using Bolt2Rule, do not type any value for this property.

IJUAhsBolt2Rl::Bolt2Rule

Defines an HgrSupportRule that returns a part number or the part class to use for the Bolts. The hanger rule must exist in the catalog; it can be a rule name or a ProgID. To specify the part directly using Bolt2Part, do not type any value for this property.

IJUAhsBolt2Qty::Bolt2Quantity

Specifies the quantity of bolts to include on BasePlate2. Usually, 2 or 4.

The following properties is applicable to I-Frame type only:

IJUAhsFrGrout::GroutPart

Specifies the part number or the part class of the grout part. For example Plate part number. To select the part using GroutRule, do not type any value for this property.

IJUAhsFrGroutRl::GroutRule

Defines an HgrSupportRule. The hanger rule must exist in the catalog; it can be a rule name or a ProgID. To specify the overhang value directly using GroutPart, do not type any value for this property.

IJUAhsFrGroutTh::GroutThickness

Specifies the thickness of the GroutPart.