Route a duct from an existing end feature - Intergraph Smart 3D - Help

Intergraph Smart 3D HVAC

Language
English
Product
Intergraph Smart 3D
Subproduct
HVAC
Search by Category
Help
Smart 3D Version
12.1 (2019)
  1. Select the end of the required duct in the model.

  2. Click Route Duct Command .

  3. If necessary, change the cross section of the current duct using the options on the ribbon.

    When you change a cross section, the software automatically inserts a transition feature.

  4. Change the routing direction, if needed.

    When you change routing direction, the software automatically inserts or changes the turn feature. Additional information appears later in the Notes section.

  5. Click in the graphic view to place the end point.

  6. Continue routing or right-click to exit the command.