After selecting an end feature or nozzle to insert the transition feature, click Properties on the Insert Transition Ribbon.
-
On the General Tab (Duct Transition Feature Properties Dialog), choose the parent duct run for your transition using the Duct Run box. Choosing More in this box allows you to choose from all duct runs associated with the active system.
-
Set the values for Type, Length, Throat Radius, Angle, and Tightness in the appropriate boxes, if necessary.
-
On the Cross Section tab of the Transition Properties dialog box, complete any necessary adjustments to the shape and dimensions of the transition for the needed flow rate.