Modify component weight attributes - Intergraph Smart 3D - Help

Intergraph Smart 3D HVAC

Language
English
Product
Intergraph Smart 3D
Subproduct
HVAC
Search by Category
Help
Smart 3D Version
12 (2018)
  1. Click Select , and then click on the duct part.

  2. Open the duct part Properties page.

    OR

    If you selected a duct feature, open its Properties page, click the Relationships tab, select Base Part in the Type box, and click Go To.

  3. Enable Dry WCG Origin and Wet WCG Origin by clicking the Occurrence Tab and setting the category to Weight and CG.

  4. Select Defined in the Dry WCG Origin or Wet WCG Origin fields. Do not select Compute; you will be unable to edit the weight attributes.

  5. Key in the required values for the following fields: Dry Weight, Wet Weight, Dry CogX, Dry CogY, Dry CogZ, Wet CogX, Wet CogY, Wet CogZ. You can select dry weight, wet weight, or both.

  6. Click OK on the Properties page.