  1. Select the duct features to change by holding down the SHIFT key while selecting all the duct features along the run.

  2. Click Properties on the horizontal ribbon.

  3. On the Duct Feature Properties dialog box, click the Cross Section Tab.

  4. Change the dimensions for the selected features as needed. Be aware that the software does not automatically recalculate dimensions of existing duct.

  5. If needed, switch the local axis of the duct associated with the width axis of the offset cross section by changing the orientation angle. By default the width is associated with the U-axis.

  6. Type the number of degrees to change the angle of the selected cross section in the Orientation Angle box.