HVACSpec Sheet - Intergraph Smart 3D - Reference Data - Hexagon PPM

Intergraph Smart 3D HVAC Reference Data

Language
English
Product
Intergraph Smart 3D
Subproduct
HVAC
Search by Category
Reference Data
Smart 3D Version
13

The HVACSpec sheet in the HVAC.xls workbook defines the specifications that are available to you for HVAC routing.

SpecName

Type the specification name of the HVAC specification objects (for example, Spec-0).

Service

Type a description of the service for the HVACSpec object. An example is NoService.

PressureClass

Type the pressure class of the HvacSpec object. Examples are LowPressure and MediumPressure.

WidthAndDepthControlOpt

Specifies whether typed values for Width and Depth are allowed in the ribbon bar. Type 1 to use system specified values for Width and Depth or type 2 to enable typed values. Based on these values the software determines if the duct specification allows user-defined Width and Depth.

HvacPartGenerationBasis

Specifies whether breaks on the feature boundary are enabled or disabled. Type 1 to disable breaks or type 2 to enable breaks. Based on this value, the software determines if the continuous part that you are routing is terminated in case of a feature break.

RunChangeAtCSChangeOption is not included in the HVAC.xls. You need to add this option to the HVACSpec sheet, and then bulkload.

LiningMaterial(Type/Grade)

Type a phrase that describes the type or grade of the lining material.

InsulationMaterial(Type/Grade)

Type a phrase that describes the type or grade of the insulation material.

DuctMaterial(Type/Grade)

Type a phrase that describes the type or grade of the duct material.

The duct material is defined in the Material sheet of the AllCommon.xls file.

Shapes

Type the name of the shape of the object. There is a relationship between the spec object and the cross section shape object. Options include Rectangular, Round, and FlatOval.

PartNumber

Lists each available part number. Type the phrase that identifies the part number. Examples include:

  • PDS-100

  • PDS-150

  • PDS-200

  • PDS-250

  • PDS-300

  • PDS-350

  • PDS-400

  • RECTFF - Rectangular flat flange

  • ROUNDFF - Round flat flange

  • ROUNDSLEEVE

  • RectSleeve - Rectangular sleeve

  • B-100 - B represents bend.

  • TA-100X80 - T represents tee. 100x80 is a reducing tee. Header is 100mm diameter of the round tee, Width, Branch is 80mm to arrive at the bend width.

  • HVACElbowFo

  • DivisionW2

  • SM1PTapSWhalfin - Surface- mounted piping tap on a duct surface that is socket- welded. halfin is one-half inch nominal pipe diameter

  • SM1PTapFThalfin - Surface- mounted piping tap on a duct surface that is female- threaded. halfin is one-half inch nominal pipe diameter

  • AirFilterHumidifier400x200x275

  • AirFilterHumidifier300x200x225

  • AirFilterHumidifier400x250x275

  • AirFilterHumidifier250x200x200

  • AirCoolingCoil400x200x350

  • AirCoolingCoil300x200x325

  • AirCoolingCoil400x250x350

  • AirCoolingCoil250x200x300

  • AirFilter400x200x180

  • AirFilter400x200x180

  • AirFilter300x200x150

  • AirFilter400x250x180

  • AirFilter250x200x120

  • MRD-URD-100

  • MRD-URD-150

  • MRD-URD-200

  • MRD-URD-250

  • MRD-URD-300

  • MRD-URD-350

  • MRD-URD-400

  • Icover400x600

  • Icover250x400

  • DivisionW3-01

  • SM-501-N

  • SM-501-P

  • RWX-N

  • SL-2000-P

  • STS-100

  • STS-50

  • STS-25

  • SHP24-1575W

  • SHP24-1575R

  • RoundWeld

  • RectWeld

  • RoundRivet

  • RectRivet

  • FlatOvalWeld

  • FlatOvalRivet

  • Rect_SlopedFlange

  • Round_SlopedFlange

  • RectTee1

  • SMRectangularBranch1

  • SMRoundBranch1

  • HVACsqrThroatElbow01

  • Round Bellmouth 300x250

  • RoundxFlatOval Bellmouth 355x1450

SectionName

Contains names of cross sections from the AllCommon.xls workbook that are valid for the specification. Examples are OCS-4X4, OCS-6X4, OCS-8X4, OCS-6X6, OCS-10X4, OCS-8X6, OCS-7X7, OCS-14X4, OCS-8X7, OCS-16X4, OCS-10X6, OCS-8X8, OCS-9X7, OCS-12X6, OCS-10X7, OCS-9X8, OCS-10X8, and OCS-14X6.

There must be at least one valid SectionName for each specification. Otherwise, only rectangular shapes can be routed.