Assigns names and other properties to knuckle, tangent, and reference curves. In the Geometry Analysis and Repair task, you can quickly and easily place attributes on knuckle, tangent, and reference curves using the Reference Curves command.

You use the Reference Curves command with the Advanced Curve Operations command. First, you create the curves with a merge operation in the Advanced Curve Operations command. Then, you assign properties to the curves using the Reference Curves command.

Reference Curves Ribbon

How to review Reference Curves

  1. Click Reference Curves .

  2. Select a wire-body in a graphic view.

  3. Check the name, symmetry, and type values on the ribbon, and change them, if necessary.

    If you choose Port/Starboard in the Symmetry box, the software creates the symmetric curve for you.

  4. Click Apply Attributes .

You can revert back to the original values on a reference curve by clicking Undo on the ribbon before applying the change. The Name, Symmetry, and Type properties are reset. The software also deletes the symmetrical starboard copy, if it was created.