Sets options for a foundation port on an equipment object.

Placement Type

Specifies a location type for the nozzle. The following location types are available for foundation ports:

Placement Type

Description

Radial

Straight foundation port with centerline on the radial plane.

Tangential

Straight foundation port on the radial plane, but the port centerline does not intersect the vessel axis.

Axial

Straight foundation port normal to radial plane.

Skew

Straight foundation port that is tilted from both the radial plane and the vessel axis.

Offset Skew

Skew foundation port with a parallel offset in the radial plane.

Position by Point

Available with all foundation ports.

Position by Plane and Axis

Available with all foundation ports.

Property

Identifies the location parameters of the selected foundation port.

Value

Shows the current values for all location parameters of the selected foundation port. You can modify these values during the initial placement of the foundation port to reflect exact design needs or deviations from the standard part.