To connect two cable trays or cableways using Move :

  • For inline connections, the two cable tray ends or cableway ends must be collinear to each other.

  • For branch connections, the header and branch runs must be orthogonal to each other.

  • There should be sufficient space at the connection to accommodate the connecting part. If the space is not sufficient, the software does not make a connection and displays a message suggesting that you manually to connect the cable trays.

  • The software consumes the first available straight feature of the moved cable tray to accommodate the connection thickness, such as a mating part.

  • In a partial move, if the connection results in an overlap the software connects the two ends with a To Do Record to maintain the connectivity.

  • If there is no space to accommodate the mating part, the software does not connect the two ends and displays a message suggesting that you to connect the ends manually.

Inline Connection

No.

Route Object

Approval Status

Permission Group Access

1

Cable tray A

Working

Full control/ Write

2

Cable tray B

Working

Full control/ Write

Result: The software connects the cable trays A and B, but does not merge the cable trays into a single cable tray.

No.

Route Object

Approval Status

Permission Group Access

1

Cable tray A

Working

Full control/ Write

2

Cable tray B

Working

Full control/ Write

3

Mating part associated with cable tray B

Result: The software connects the two cable trays with a mating part. Reduction in cable tray B straight length = mating part length.

No.

Route Object

Approval Status

Permission Group Access

1

Cable tray A

Working

Full control/ Write

2

Cable tray B

Working

Full control/ Write

3

Connection overlap

Result: The software does not connect the cable trays because there was not enough space to accommodate the transition part. The software displays a message suggesting that you to connect the trays manually.

Branch Connection

No.

Route Object

Approval Status

Permission Group Access

1

Header run

Working

Full control/ Write

2

Branch run

Working

Full control/ Write

3

Vertical tee connection associated with the header

Result: The software connects the header and branch runs using a system-generated vertical tee.

No.

Route Object

Approval Status

Permission Group Access

1

Header run

Working

Full control/ Write

2

Branch run

Working

Full control/ Write

3

Horizontal tee connection associated with the header

Result: The software connects the header and branch runs at the tee end feature.

No.

Route Object

Approval Status

Permission Group Access

1

Header run

Working

Full control/ Write

2

Branch run

Working

Full control/ Write

3

Connection overlap

Result: The software does not connect the cable trays because there was not enough space to accommodate the transition part. The software displays a message suggesting that you connect the trays manually.