Displays and defines the general properties of the selected conduit.

Because conduit run properties are customizable in the reference data, only the properties that are required by the software are documented.

Conduit run properties are divided into several different categories: Standard, Surface Treatment and Coating, Cable Fill, and Responsibility. You select which category that you want to define values for by using the Category option.

Standard

System

Displays or defines the system for the conduit. The last system that you selected is the default. Select More to display all defined systems. You can create a new system in the Systems and Specifications task.

Name

Displays or defines the name of the conduit that you are creating. The name is based on the Name Rule selection. If you want to type a new name for the run, in the Name Rule box, select User Defined, and then type a name for the run in the Name box.

Name Rule

Specify the naming rule that you want to use to name this run. You can select one of the listed rules or select User Defined to specify the run name yourself in the Name box.

Specification

Displays or defines the specification for the conduit. Specifications are assigned to systems in the Systems and Specifications task. Only those specifications that are allowed in the system that you selected appear. You define specifications in the reference data.

Nominal Conduit Diameter

Displays or defines the conduit diameter. The specification controls the available NPDs in this list. Select the nominal pipe diameter (NPD) that you want to use for this run. If you select a nozzle as the starting point of your conduit run, the software automatically uses the NPD of the nozzle as the NPD of the conduit run.

Behavior Controlled by User

Specifies if you control the conduit run or if the conduit run is controlled by the parent duct bank. This option is only available when the selected conduit is inside a duct bank.

If False (the default value), the conduit run is controlled by the parent duct bank. This means:

  • The conduit ends at the end of the duct bank. If you extend the conduit past the duct bank end, and later the duct bank is updated, the conduit end is repositioned back to the duct bank end.

  • Insert components on the extended part of the conduit run, but you cannot delete the component.

  • Individual conduit features inside the duct bank cannot be moved.

If True, you control the conduit run. This means you can:

  • Extend the conduit run past the end of the duct bank.

  • Insert and delete components on the extended part of the conduit run.

  • You can move individual conduit features inside the duct bank.

Surface Treatment and Coating

Interior Surface Treatment Type

Select the type of interior surface treatment for the conduit. If you want to add, edit, or remove values that are available for selection, edit the Interior Surface Treatment sheet in the AllCodeLists.xls workbook in the reference data.

Interior Surface Treatment Requirement

Select the interior surface treatment requirement for the conduit. If you want to add, edit, or remove values that are available for selection, edit the Interior Surface Treatment sheet in the AllCodeLists.xls workbook in the reference data.

Exterior Surface Treatment Type

Select the type of exterior surface treatment for the conduit. If you want to add, edit, or remove values that are available for selection, edit the Exterior Surface Treatment sheet in the AllCodeLists.xls workbook in the reference data.

Exterior Surface Treatment Requirement

Select the exterior surface treatment requirement for the conduit. If you want to add, edit, or remove values that are available for selection, edit the Exterior Surface Treatment sheet in the AllCodeLists.xls workbook in the reference data.

Cleaning Requirement

Select the cleaning requirement for the conduit. If you want to add, edit, or remove values that are available for selection, edit the Cleaning Requirement sheet in the AllCodeLists.xls workbook in the reference data.

Steamout Requirement

Select the steamout requirement for the conduit. If you want to add, edit, or remove values that are available for selection, edit the Steamout Requirement sheet in the AllCodeLists.xls workbook in the reference data.

Steamout Pressure

Specify the steamout pressure for the conduit. Include the pressure unit of measure, psi for pounds per square inch for example, when specifying this value.

Steamout Temperature

Specify the steamout temperature for the conduit. Include the temperature unit of measure, K for Kelvin, F for Fahrenheit, or C for Celsius for example, when specifying this value.

Interior Coating Requirement

Select the coating requirement of the interior coating for the conduit. If you want to add, edit, or remove values that are available for selection, edit the Coating Type sheet in the AllCodeLists.xls workbook in the reference data.

Interior Coating Type

Select the type of interior coating for the conduit. If you want to add, edit, or remove values that are available for selection, edit the Coating Type sheet in the AllCodeLists.xls workbook in the reference data.

Interior Coating Area

Enter the total area that the interior coating covers.

Exterior Coating Requirement

Select the coating requirement of the exterior coating for the conduit. If you want to add, edit, or remove values that are available for selection, edit the Coating Type sheet in the AllCodeLists.xls workbook in the reference data.

Exterior Coating Type

Select the type of exterior coating for the conduit. If you want to add, edit, or remove values that are available for selection, edit the Coating Type sheet in the AllCodeLists.xls workbook in the reference data.

Exterior Coating Area

Enter the total area that the exterior coating covers.

Coating Color

Select the color of the conduit coating. If you want to add, edit, or remove values that are available for selection, edit the Coating Color sheet in the AllCodeLists.xls workbook in the reference data.

Cable Fill

Fill Efficiency

Displays or defines the efficiency of the stacking of cables in the conduit. You can enter a real number, integer, or percent; for example, type 0.9, 90, or 90%.

Signal Type

Displays or defines the cable usage, which is used in tray fill calculations. If you want to add, edit, or remove values that are available for selection, edit the Signal Type sheet in the AllCodeLists.xls workbook in the reference data.

Voltage Grade

Displays or defines the voltage grade, which is used in determining the range of voltage that the conduit can carry. If you want to add, edit, or remove values that are available for selection, edit the Voltage Grade sheet in the AllCodeLists.xls workbook in the reference data.

Responsibility

Cleaning Responsibility

Select the party responsible for cleaning the conduit. If you want to add, edit, or remove values that are available for selection, edit the Cleaning Responsibility select list in the Catalog task.

Design Responsibility

Select the party responsible for designing the conduit. If you want to add, edit, or remove values that are available for selection, edit the Design Responsibility select list in the Catalog task.

Fabrication Responsibility

Select the party responsible for fabricating the conduit. If you want to add, edit, or remove values that are available for selection, edit the Fabrication Responsibility select list in the Catalog task.

Installation Responsibility

Select the party responsible for installing the conduit. If you want to add, edit, or remove values that are available for selection, edit the Installation Responsibility select list in the Catalog task.

Painting Responsibility

Select the party responsible for painting the conduit. If you want to add, edit, or remove values that are available for selection, edit the Painting Responsibility select list in the Catalog task.

Requisition Responsibility

Select the party responsible for ordering the conduit. If you want to add, edit, or remove values that are available for selection, edit the Requisition Responsibility select list in the Catalog task.

Supply Responsibility

Select the party responsible for delivering the conduit. If you want to add, edit, or remove values that are available for selection, edit the Supply Responsibility select list in the Catalog task.

Testing Responsibility

Select the party responsible for testing the conduit. If you want to add, edit, or remove values that are available for selection, edit the Testing Responsibility select list in the Catalog task.