Add or remove a single conduit in a duct bank - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3D Electrical

Language
English
Product
Intergraph Smart 3D
Subproduct
Electrical
Search by Category
Help
Smart 3D Version
13.1
  1. Click Select .

  2. Select Cableways in the Locate Filter box.

  3. Select the duct bank to modify.

  4. Click Properties on the ribbon.

  5. Select the Duct Bank tab.

  6. On the Duct Bank tab, click Add Conduit Run to add another conduit.

    The software adds a conduit run named AddedRun<N> to the duct bank at 0x0 position. You can see the preview of the conduit run and its position.

  7. To change the position of the new conduit run, modify the Distance Along Width Direction and Distance Along Depth Direction as required.

    SHARED Tip If the new position is outside the cross section, click Resize to adjust the cross section.

  8. Click OK to confirm the changes and close the dialog.

  • To revert the changes, click Go To Defaults Go to Defaults, or click Cancel.

  • To delete a conduit, click Delete ICON Remove.