Define Conduit Nominal Diameters - Intergraph Smart 3D - Reference Data

Intergraph Smart 3D Electrical Reference Data

Language
English
Product
Intergraph Smart 3D
Subproduct
Electrical
Search by Category
Reference Data
Smart 3D Version
11 (2016)
  1. Open the Conduit.xls workbook.

  2. Select the Conduit Nominal Diameters sheet.

  3. Select a row after the Start keyword but before the End keyword and click Insert > Rows.

  4. In the Spec Name column, type the name of your conduit materials class.

  5. In the NPD column, type the nominal diameters that you want to define in your conduit materials class.

  6. In the NPD Unit Type column, type the units for your nominal diameter. For example, type mm or in.

  7. Type A in the first column of the added rows.

  8. Save the workbook and exit.

  9. Bulk load the workbook in the Add/Modify/Delete mode.

The conduit materials class must be defined on the Conduit Spec sheet.

See Also

Permissible Nominal Conduit Diameters Rule