The Cableway Nominal Sizes node (the sheet in the Ductbank.xls workbook) controls which cross sections are available in the specifications. The sizes relate to the rectangular cross sections.
SpecName
Identifies the duct bank specification for the cross section; that is, DBS-0.
SectionName
Identifies the outfitting cross section (OCS). Examples are OCS-4X4, OCS-6X4, and OCS-6x6. These cross section examples are defined in the OutfittingCrossSections sheet. If you include cross section names using this sheet, the names must be defined on this sheet in AllCommon.xls.