The Cable Way Specifications node (the Cableway Spec sheet in the CableWay.xls workbook) determines the specification that you access when you route a new run of cableway or create cableway features such as transitions and turns.
Default Bend Radius
Specifies the default for the throat radius width. Example values for bend radii are 12in, 24in, and 36in.
Description
Specifies a phrase that describes the cableway specification. For example, you can explain the purpose of this particular specification.
Fitting to Fitting Connection Part #X Component Class
Leave undefined.
Fitting to Fitting Connection Part #X Component Type
Leave undefined.
Fitting to Fitting Connection Part #X Quantity
Leave set to 0.
Tray Specification Type
Indicates if the specification applies to cable trays, cableways, or duct banks. "1" represents Cableway, "2" represents Cable tray, and "3" represents Duct Bank. Valid codes are listed in the AllCodeLists.xls workbook on the TraySpecificationType sheet in the Codelist Number column.
Load Span Classification
Leave undefined.
Load Span Classification Practice
Leave undefined.
Manufacturer
Specify the manufacturer of the material in the reserved cableway space. This property is used to track the manufacturer for reporting. Valid codes are listed in the AllCodeLists.xls workbook on the Manufacturer sheet in the Codelist Number column.
Material
Specifies the material that will reside in the reserved cableway space.
Preferred Connection Gap
Leave set to 0.
Rung Spacing
Leave set to 0.
Spec Name
Specifies the name assigned to the cableway specification.
Tray to Fitting Connection Part #X Component Class
Leave undefined.
Tray to Fitting Connection Part #X Component Type
Leave undefined.
Tray to Fitting Connection Part #X Quantity
Leave set to 0.
Tray to Tray Connection Part #X Component Class
Leave undefined.
Tray to Tray Connection Part #X Component Type
Leave undefined.
Tray to Tray Connection Part #X Quantity
Leave set to 0.
Tray Length
Leave set to 0.
Tray Type
Leave undefined.