Orientation - Intergraph Smart 3D - Reference Data

Intergraph Smart 3D Drawings and Reports Reference Data

Language
English
Product
Intergraph Smart 3D
Subproduct
Drawings and Reports
Search by Category
Reference Data
Smart 3D Version
12 (2018)

Specifies the orientation of a plate or profile with respect to the target plate defined in the view.

This custom test applies to systems and parts.

1

Orientation = Target

  • The target object. The Level custom test is set to 0. For more information, see Level.

2

Orientation = Non-target

  • A plate part or system normal is perpendicular to the view direction.

  • A plate part or system normal is normal to other targets.

  • A profile part or system is on the non-target plate.

3

Orientation = Target

  • The normal of a plate part or system is parallel to the view direction.

  • The normal of a plate part or system is aligned in the same direction as other targets.

  • A profile part or system is on the target plate.

Direction of view