The Primary/Secondary Side Length label templates use the default value, Length, from the IJWeldingSymbol property.
-
To create a new label template, do the following:
-
Create a new label in the [Reference Data Folder]\SharedContent\Drawings\Catalog\Labels\Templates\WeldSymbols folder. For information about creating labels, see Create a Label.
-
Select the label template you just created from the Label Template list.
The software does not include Primary Side or Secondary Side in the label template name.
-
Click Save on the Symbol Configuration tab.
The software updates the label template XML as shown below.
Usage in Label Template XML
<contentModuleSettings>
<ID attributeName="PrimarySideLength"
visible="1">WeldSymbols\Primary Side Length.rtp</ID><ID attributeName="SecondarySideLength"
visible="1">WeldSymbols\Secondary Side Length.rtp</ID></contentModuleSettings>
Primary Side
Used only for intermittent welds. This value sets the nominal length of individual weld segments.
Secondary Side
Specifies the nominal length of individual weld segments. This value is used only for intermittent welds.