Places an angular dimension. The dimension is based on paper space in the view. This module is only used by the penetration plate dimensioning in Piping Isometric Drawings.

Usage in Label Template XML

<label>
<content>
<contentModule value="DrawingDimContAngNoReplace"/>
<ignoreError>-1</ignoreError>
</content>
</label>

Customization

ignoreError

Specifies whether or not the system places a label if the software returns no content or an error for the label.

Type -1 to suppress the label when an error occurs.

ignoreLabelContentError2

1 - Error label

Type 0 to display the label regardless of an error.

ignoreError display label

1 - Empty label