A SeamPointAE does not have a related profile system - Intergraph Smart 3D - Administration & Configuration - Hexagon

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
13

Message

A SeamPointAE does not have a related profile system.

Severity

Fatal.

Detailed Description

A seam point active entity (AE) does not have a related profile system. Possible situations:

  • Missing the SeamPoint_Int_Profile relationship to (ProfileSystem, EdgeReinforcementSystem or BeamSystem) for SeamPointIntersect_AE

  • Missing the SeamPointOffsetProfile relationship to (ProfileSystem, EdgeReinforcementSystem or BeamSystem) for SeamPointOffset_AE

Possible Causes

Unknown.

Possible Impacts

You cannot manipulate the object itself or other objects related to it.

What You Should Do

  1. Open the model.

  2. In the Molded Forms task, select the object, and modify it, if necessary. Or, select the object, and perform a re-computation to update it.

  3. Re-run the Check Database Integrity custom command and the DBIntegrity report.

  4. If the object is still posted, contact Smart 3D Support.