Axis joint copy property flag is not zero or the point on value is not -1.0 - Intergraph Smart 3D - Administration & Configuration - Hexagon

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
13.1

Message

Axis joint copy property flag is not zero or the point on value is not -1.0.

Severity

Normal.

Detailed Description

The axis joint provides the connection between two member systems. When an axis joint is copied, the properties are altered to facilitate the copy; however, these properties should not be set persistently in the database.

Possible Cause

A copy operation prematurely failed; however, the transaction was allowed to continue with these copy properties set on the axis joint.

Possible Impacts

The next graphical modification of the member systems connected to this axis joint may behave differently where all point-on member systems will maintain a relative distance along similar to how copy behaves.

What You Should Do

Because axis joints are not first class objects, there is little one can do to manually correct the problem.

  1. Ask your database administrator to back up the model.

  2. Send the backup and any information that may have led to this error to customer support. You can find support information on our web site at Hexagon Customer Support.

As members are manipulated in the model, this error will disappear from the list of integrity errors.