BracketByPlane PlateSystem's PlaneByOffset PlateGeometry is not an input to the symbol's ReferenceCollection - Intergraph Smart 3D - Administration & Configuration - Hexagon

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
13.1

Message

BracketByPlane PlateSystem's PlaneByOffset PlateGeometry is not an input to the symbol's ReferenceCollection.

Severity

Crucial.

Detailed Description

A BracketByPlane PlateSystem's PlaneByOffset PlateGeometry must be an input to the symbol's ReferenceCollection. The symbol needs information from this geometry.

Possible Cause

Unknown.

Possible Impacts

The geometry and display of the PlateSystem will not be correct. This problem can affect other related objects.

What You Should Do

  1. Open the model.

  2. In the Molded Forms task, select the BracketByPlane PlateSystem, select a valid symbol, and make any other necessary modification.

  3. Re-run the Check Database Integrity custom command and the DBIntegrity report.

  4. If the object is still posted, contact Smart 3D Support.