A StructPortAE exists without having related geometry - Intergraph Smart 3D - Administration & Configuration - Hexagon

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
13.1

Message

A StructPortAE exists without having related geometry.

Severity

Crucial.

Detailed Description

A structural port active entity (AE) exists without having related geometry: Missing the StructGeometryHasPorts relationship to IJStructGeometry (various) for StructPort_AE.

Possible Cause

Unknown.

Possible Impacts

Cases found were for CollarParts, PlateParts and StiffenerParts. In the cases examined, another StructPort_AE was available and properly related to Geometry, Ports, and Parts. Therefore, it is recommended to delete or remove the StructPort_AE that is in error.

It is possible that the bad StructPort_AE is being returned to code that is attempting to use it, because related items were also found on the To Do List, for example, unnamed collar parts and MfgParts.

What You Should Do

  1. Ask your database administrator to back up the model.

  2. Supply all information possible that may have led to this situation, and submit this information along with the backup to Smart 3D Support.

  3. Run the Clean Database custom command to delete the object.