A Plate cutout operation exists with no related operator - Intergraph Smart 3D - Administration & Configuration - Hexagon

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
13.1

Message

A Plate cutout operation exists with no related operator.

Severity

Crucial.

Detailed Description

A Plate cutout operation exists with no related operator: Missing the PlateCutout_OPER1 relationship to the Sketch (reference proxy – symbol) information for PlateCutout_AE.

To facilitate TR 104211, the current DB Integrity check has been changed to post the Plate cutout operation (PlateCutout_AE) with an action of DELETE.

In order to make it more convenient for finding and posting such cases, this particular query has been moved to the CheckAEWithSketches.sql file.

Possible Cause

Unknown.

Possible Impacts

When the sketch information for an opening on a Plate is missing, it is no longer possible to update parts on the plate system or place new openings.

What You Should Do

  1. Ask your database administrator to back up the model.

  2. Supply all information possible that may have led to this situation, and submit this information along with the backup to Smart 3D Support.

  3. Delete the object using the Clean Database custom command.