Message
Equipment does not have a system parent.
Severity
High.
Detailed Description
The equipment is not related to its system parent anymore. This situation is unexpected.
Possible Causes
-
The cause at run time is currently unknown.
-
The cause could be external, for example, database manipulation.
Possible Impacts
-
Some commands may work incompletely.
-
You cannot copy the equipment to the catalog. If you try, an error appears: No required inputs were generated. If inputs were required, this may be a problem. When you click OK, the software displays an application error.
-
Equipment reports are possibly erroneous or inaccurate.
-
It is impossible to retrieve equipment using filters and style rules based on systems.
What You Should Do
If the problem is local to one or a few equipment:
-
Open the model.
-
Delete the equipment.
-
Save the session.
-
Refresh all session files with a workspace including the equipment.
If the problem is widespread on all equipment:
-
Restore your most recent backup using the Project Management task.
-
Refresh your session files.