Validates the internal connections between objects on a P&ID and objects in the Model database. This command is a custom command (ProgID: SP3DDisplayPIDService.VerifyPIDCmd) and provides some basic troubleshooting statistics. It does not resolve database integrity errors. For more information about database integrity, see the Database Integrity Guide available from the Help > Printable Guides command in the software.

The Verify P&ID Integrity command displays the following information:

  • Design Basis Objects: The total number of design basis objects that have a relationship to the P&ID document object. The number should be the same as what is seen in the P&ID Viewer.

  • 3D Objects: The number of design basis objects that have a correlated relationship between the P&ID document and the Smart 3D object. The current correlation status is also reported.

  • P&ID Objects (Total Identified): This count is the total number of RAD objects that have a drawing ID in the P&ID document. The total identified should match the number of Design Basis Objects. These objects are displayed with their representation ID.

  • P&ID Objects (contained in Design Basis): The number of RAD objects that have a graphic OID that will map to drawing representation design basis objects. This number should match the Design Basis Object count. A mismatch most likely means that the objects were deleted. The difference is the number of Deleted P&ID OIDs.

  • Deleted P&ID OIDs: The number of RAD objects that have a graphic OID but do not exist in the model.

  • Duplicate OIDs: The number of multiple RAD objects with the same graphic OID. Most likely, there is a problem with the P&ID file or with the integrated environment.

  • Miscellaneous Errors - Any errors not defined above are in this category.

What do you want to do?

View P&IDs