Define Corrosion Allowances - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3D Catalog

Language
English
Product
Intergraph Smart 3D
Subproduct
Catalog
Search by Category
Help
Smart 3D Version
13
  1. In the tree view, click Piping > Piping Specification > Piping Materials Classes.

  2. In the Piping Materials Classes branch, open a specification and click Piping Materials Class Rules > Corrosion Allowance.

  3. Click the Insert Row Command to insert a blank row in the grid view.

  4. In the Materials Category column, enter the materials code for which you are defining corrosion allowance.

  5. In the Fluid Code column, enter the fluid code for which you are defining corrosion allowance.

  6. In the Corrosion Allowance column, specify the corrosion allowance for the specified material and fluid codes. Be sure to include the units of measurement, in or mm, when specifying this value.

  • Valid material codes are defined in the Material Grade select list.

  • Valid fluid codes are defined in the Fluid Code select list.

  • The Corrosion Allowance sheet in the Piping Materials Class.xls workbook corresponds to the Corrosion Allowance node in the Catalog task. See Piping Reference Data.