Define Flared Pipe Information - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3D Catalog

Language
English
Product
Intergraph Smart 3D
Subproduct
Catalog
Search by Category
Help
Smart 3D Version
13.1
  1. In the tree view, click Piping > Piping Specification > Model Rules > Flared Pipe node.

  2. Click the Insert Row Command to insert a blank row in the grid view.

  3. In the Nominal Pipe Diameter column, enter the pipe diameter for which the information applies.

  4. In the Schedule Thickness column, enter the schedule thickness for which the information applies.

  5. In the Lap Length column, enter the lap length. Be sure to include the units of measure, for example in or mm, when specifying this value.

  6. In the Lap Thickness column, enter the lap thickness. Be sure to include the units of measure, for example in or mm, when specifying this value.

The Flared Pipe sheet in the workbook corresponds to the Flared Pipe rule node. See Piping Reference Data.