Define NPD Compatibility Exceptions - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3D Catalog

Language
English
Product
Intergraph Smart 3D
Subproduct
Catalog
Search by Category
Help
Smart 3D Version
13.1
  1. In the tree view, click Piping > Piping Specification > Model Rules > Nominal Piping Diameter Compatibility Exceptions Rule.

  2. Click the Insert Row Command to insert a blank row in the grid view.

  3. In the Nominal Piping Diameter End A column, enter the nominal pipe diameter for the end of the applicable joint that represents End A.

  4. In the Nominal Piping Diameter Units End A column, type the units for the NPD on End A. For example, type mm or in.

  5. In the Materials Practice End A column, select the industry practice for the materials grade of the fitting at End A. For example, select German Standards (DIN).

  6. In the Materials Category End A column, select the classification for the materials grade of End A.

  7. In the Nominal Piping Diameter End B column, enter the nominal pipe diameter for the end of the applicable joint that represents End B.

  8. In the Nominal Piping Diameter Unit End B column, type the units for the NPD on End B. For example, type mm or in.

  9. In the Materials Practice End B column, select the industry practice for the materials grade of the fitting at End B. For example, select German Standards (DIN).

  10. In the Materials Category End B column, select the classification for the materials grade of the fitting at End B.

  11. Click the Save Command Save.

The NPD Compatibility Exceptions Rule sheet inhttps://hexagonppm.com/support/ppm-smart-community workbook corresponds to the Nominal Piping Diameter Compatibility Exceptions Rule node. See Piping Reference Data.