The following tables lists common warning and information messages that can appear in the Errorlog.txt file produced during the PDS conversion process.

Warning Messages

Message

Meaning

Warning - Cannot Determine Bolt Data from ...\Physical\xxx - no bolts created for - xxx

An error occurred when reading the specified bolting file. Check the eden code.

Warning - Cannot determine range of second bores from Weight Table xxx Component omitted.

A single bore was specified for a reducing component. The range of second bores must be determined from the weight file. An error occurred trying to read this file. Check the eden code.

Warning - Cannot find Match in Size Dependent data for xxx Bore xxx No components created.

A match for the component could not be found in the size dependent data file. Check the units

Warning - No Description for xxx Bore xxx No components created.

No match could be found in the short description file for the component.

Warning - Error Reading Dimension Mapping for xxx with SKEY : xxx

An error occurred reading the equation.map file or the mapequations.txt file.

Warning - Cannot determine dimensions for xxx with SKEY : xxx  Please provide dimension mapping.

An error occurred when trying to determine the dimensions from the eden code. Provide mapping for this component.

Warning - Error Reading physical data file ...\Physical\xxx - no components created for - xxx

An error occurred when trying to read the physical data file. Check its format / content.

Warning - Cannot Determine OD for xxx Bore xxx - No Components Created.

An entry in the TDMALxxx table could not be found for the given OD. Check the units / eden code and or TDMALxxx table.

Warning - No Value Specified in User Elbolet Data File for xxx Bore xxx - No Components Created.

An entry for the given bore could not be found in the user specified elbolet dat file. Check the units and the file contents.

Warning - Cannot find associated component for xxx No Dimensions for this component.

An associated component could not be found (e.g. tbacking flange / stub end). Check the specification.

Warning - Error determining component data from pcd entry : xxx

The component dimensions are missing from the PCD file. Check the value in the modifier column

Warning - Error Reading Fixed Pipe Length Table xxx

The format of the fixedpipe.txt file is invalid.

Warning - Can't find Length in PCSD Modifier code for xxx Component Omitted.

The component dimensions are missing from the PCD file. Check the value in the modifier column

Warning - Invalid Mapping for xxx Skey xxx" Component Omitted.

The mapping as specified in the equation.map or mapequations.txt file is invalid.

Warning - Invalid mapping for component xxx Output n is Invalid - Component has been omitted."

Output n has been specified in the mapequations.txt file OR the eden code – this output does not exist. Check the mapequations.txt file or the eden code.

Warning - NoConfiguration Found for xxx with Skey xxx Component Omitted."

The skey does not exist in the skey.tbl or the skeyuser.tbl

Warning - Error Decoding Physical Data File - no component created for xxx

An error was encounter reading  / decoding the physical data source file. Check the eden code.

Warning - Missing Commodity File ...\Commodity\xxx - no component created for - xxx

The specified commodity file is missing. Check the eden code.

Warning - Error Decoding Symbol Processor File ...\Commodity\xxx - no component created for – xxx

An error occurred reading the symbol processor file. Check the eden code

Warning - Missing Symbol Processor File ...\Commodity\xxx  - no component created for – xxx

The symbol processor file is missing. Re-extract the commodity data.

Warning - Cannot find Physical File ...\Physical\xxx - no component created for -  xxx

Cannot find the specified physical data file. Re-extract all the physical data (ensure all practices used are extracted). Check the eden code.

Warning - Cannot find Physical File Reference from ...\Commodity\xxx - no component created for – xxx

A reference to the physical data file could not be found. Check the eden code.

Warning - Error Reading Commodity File ...\Commodity\ - no component created for - xxxAn error occurred reading the commodity file – check eden code.

An error occurred reading the commodity file. Check eden code.

Information Messages

Message

Meaning

Information - No Match for Component xxx with Bore xxx In Physical File x...\Physical\xxx

Could not find a component in the specified file. Check the eden code.

Information - Unknown Label Component xxx for Commodity Code xxx

The label component is unknown. Check the value in the label file.

Information - Cannot Decode Label Number xxx for Commodity xxx Bore xxx

An error occurred while trying to decode a label.

Information - Cannot Determine Radius for Trimable Elbow (xx Degree Assumed) xxx

The specified angle string could not be found in the description. The reported angle is assumed.

Information - Standard Note File ...\Dat\CODExxx Cannot be found [n] Has not been decoded for xxxxx Bore xx

The Standard Note file Codexxx.edt is missing from the Dat sub-directory. The requested note number cannot be determined.

Information - Note Number [n] Cannot be found in Standard Note file ...\Dat\CODExxx Label has not been decoded for xxxxx Bore xx

The Standard Note file Codexxx.edt does not contain the requested Note number. The requested note number cannot be determined.