Unable to open the SDx Desktop Client after upgrading the SDx Connector for Plant Maintenance to version v10.0.42.10 - HxGN SDx - v10 - Installation & Upgrade - Hexagon

HxGN SDx Connector for Plant Maintenance Installation and Configuration

ft:locale
en-US
Product
HxGN SDx
Subproduct
HxGN SDx Connectors
Search by Category
Installation & Upgrade

Error Message

You get the following error when you open the SDx Desktop Client after upgrading the SDx Connector for Plant Maintenance from version v10.0.22.10 to version v10.0.42.10.

'Object Reference not set to an instance of an object'

Cause

Version v10.0.22.10 of the SDx Connector for Plant Maintenance does not support side-by-side installation, and it works only with either SDx or SPF.

When you uninstall version v10.0.22.10 of the SDx Connector for Plant Maintenance after upgrading the SDx to Update 29 or later, the SpecializationValuesSDAPM.xml file remains in the site path. When you install v10.0.42.10 of the SDx Connector for Plant Maintenance, the SpecializationValues_SDxConnectors.xml file is added to the site path. The duplication of both the xml files in the site path causes an error when you open the SDx Desktop Client.

Solution

You must manually remove the SpecializationValuesSDAPM.xml file from the site path.