SG-9228 Equipment (A/P/S) | Meters | View Meter History - field Total Usage does not get updated after deleting readings - HxGN EAM - 12.1.0.2 - Release Notes/Bulletin - Hexagon

HxGN EAM Release Notes for 12.1.0.2

ft:locale
en-US
Product
HxGN EAM
Search by Category
Release Notes/Bulletin
HxGN EAM Version
12.1.0.2

SG-9228 Equipment (A/P/S) | Meters | View Meter History - field Total Usage does not get updated after deleting readings

 Description 

The system does not update field "Total Usage" after deleting last meter reading.

*Steps to Reproduce*

# Select an equipment record.

# Go to Meters tab.

# Add a meter, and make sure checkbox "Up/Down Meter" is selected.

# Click on Actions and enter a few meter readings for previous dates (e.g., Aug15th 50, Sept15th 80, Oct 15th 100)

# Then click Actions and View Meter History, select the last record and hit Delete Reading and close the popup.

# Notice field Total Usage does not change, it still shows the previous reading.

*Current Behavior*: When Up/Down Meter checkbox is selected, deleting readings does not update Total Usage

*Expected Behavior:* When Up/Down Meter checkbox is selected, deleting readings should update Total Usage.

Is this the expected behavior? And if so, what is the logic behind? I looked in the use case, but I didn't find any reference to this scenario in particular.