Wall Thickness - CAESAR II - Help

CAESAR II Users Guide

Language
English
Product
CAESAR II
Search by Category
Help
CAESAR II Version
13

Enter the thickness of the pressure vessel wall, in the displayed units. This thickness is measured at the intersection of the nozzle and the vessel.

  • You can type the wall thickness as an equation to account for mill tolerance. For example, if the mill tolerance is 12.5%, type "<vessel wall thickness value> * 0.875".

  • The software modifies this value if a value for Corrosion Allowance is defined.