Indicates whether the piping element is seam welded
B31.1 / B31.3
If the B31.1 or B31.3 piping codes are active, select the Seam-welded check box to activate the Wl box. Wl (the weld strength reduction factor) is used by the software to determine the minimum wall thickness of the element.
IGE/TD/12