  • Improved the stress calculations for ISO 14692-2017 to exclude the calculation of ring bending stress and roping stress from the algebraic combination load cases. See Curve Radius. (3673147)

Documentation/Help

CAESAR II Version 13.00

Piping Input

Static and Dynamic Analysis

  • Applied an EN-13480 2017 requirement to Pad Thk tp to limit the reinforcing pad thickness to the nominal thickness of the header. (CR-TX-40463)

  • Fixed an issue with a variable angle change for a structural element axis orientation. The issue was caused by a double conversion of the angle from degrees to radians for every elastic modulus selection in the Static Analysis - Load Case Editor Dialog. (TR-TX-39566)

  • Corrected the text for an Error Check warning when Nozzle Flexibility is specified, and the nozzle diameter is greater than one third of the vessel diameter. The text incorrectly stated vessel radius. (TR-TX-27686)