Enter the thickness of the pressure vessel wall, in the displayed units. This thickness is measured at the intersection of the nozzle and the vessel.
-
You can type the wall thickness as an equation to account for mill tolerance. For example, if the mill tolerance is 12.5%, type "<vessel wall thickness value> * 0.875".
-
The software modifies this value if there is a defined value for Corrosion Allowance.