Enter True if the nozzle is located within the spherical portion of an elliptical or torispherical head or is in a spherical head. The software accesses the Annex G curves used to calculate factors for nozzles connected to spheres.
If you enter this data manually, enter the spherical diameter. This is especially important for nozzles located in elliptical heads.