Add output feature information - CAESAR II - Help

CAESAR II Users Guide

Language
English
Product
CAESAR II
Search by Category
Help
CAESAR II Version
12

The Output tab defines what post-analysis results of a model that the software includes in the drawing. Select Load Cases on the Output tab to see the load cases the software uses to analyze the model. The analysis results are categorized as Displacement, Restraint, and Stress in the Results box. Select Hanger Data on the Output tab to see generate hanger information not specific to a load case.

  1. Select File > Open to open a model.

  2. On the Home tab, click Generate Stress Isometrics to open the model in the C2Isogen module.

  3. Select StressIso > Annotations to open the Stress Isometric Annotations pane.

    The Input tab is active by default.

  4. Select the Output tab to view the load cases used to analyze the model. Output features are available for selection only if you have analyzed the piping model. If you have not analyzed the model, click Generate Output from the Output tab.

  5. Click Load Cases to select a load case.

    The results generated for the load case are listed in the Results box.

  6. Select the result type you want, and then select the nodes to include the information for annotation.

  7. Select StressIso > Save Annotation to save annotations for the selected output information.

  • The Node number, Node Name, and Description columns display information entered in CAESAR II and cannot be edited.

  • The Load Cases list displays load cases created for static analysis only.

  • To remove a node or an element from a selection set, click the annotation tag in the display area, and then press DELETE.