Specifies r1, Tc, or Lh based on the component type.
Typical units (depending on your unit system):
-
in
-
mm
-
cm
Fabricated Tee
Specifies the r1 value. For more information on r1, see IGE\TD\12 Reference.
Forged Tee to BS 1640
Specifies the Tc value. For more information on Tc, see IGE\TD\12 Reference.
Sweepolet
Specifies the r1 value. For more information on r1, see IGE\TD\12 Reference.
Weldolet
Specifies the r1 value. For more information on r1, see IGE\TD\12 Reference.
Drawn/Extruded Tee
Specifies the Lh value. For more information on Lh, see IGE\TD\12 Reference.
Long Weldneck Flange
Specifies the r1 value. For more information on r1, see IGE\TD\12 Reference.
Weldoflange
Specifies the r1 value. For more information on r1, see IGE\TD\12 Reference.