Temperature-Pressure Table - CAESAR II - Help

CAESAR II Users Guide

Language
English
Product
CAESAR II
Search by Category
Help
CAESAR II Version
12

Specifies temperature and pressure values. Use this table to define the flange Temperature-Pressure rating as a function of temperature for a material grade. You can type up to 24 temperature-pressure pairs. These values must be typed in ascending temperature order.

Pressure - Typical units (depending on your unit system):

  • lb/in²

  • Bar

  • KPa

  • MPa

Temperature - Typical units (depending on your unit system):

  • ºF

  • ºC

Flange evaluation is based on a specific load case temperature. To evaluate the flanges in a model, specify the operating temperature at which the software evaluates the flanges in the Flange Analysis Temperature box on the Load Cases tab of the Static Analysis - Load Case Editor.