Full Length in Circumferential Dir (2*Cy) - CAESAR II - Help

CAESAR II Users Guide (2019 Service Pack 1)

Language
English
Product
CAESAR II
Search by Category
Help
CAESAR II Version
11.0 (2019)

If the attachment is square or rectangular instead of a nozzle, enter Cy, the full length of the attachment in the circumferential direction of the vessel. At the junction of the attachment with the vessel, the attachment is converted to an equivalent round attachment with the following outside radius:

ro = Sqrt(Cx * Cy)

This value is only used when PD5500 Annex G is True on the Home tab.