Output Status - CAESAR II - Help

CAESAR II Users Guide (2019 Service Pack 1)

Language
English
Product
CAESAR II
Search by Category
Help
CAESAR II Version
11.0 (2019)

Controls the disposition of the load case results. The available options are Keep or Suppress.

  • Use Keep when the load case is producing results that you want to review. The default for all new cases (except for HGR load cases) is Keep.

  • Use Suppress for artificial cases such as the preliminary hanger cases, or intermediate construction cases. Load cases used for hanger design, that is, the weight load case and hanger travel cases designated with the stress type HGR, must be designated as Suppress.